Also, dont forget to check the breather box for debris and use a vacuum cleaner or a lightly damp rag to clean the box. To learn more about error code 14, read this in-depth guide. The fan motor should also have the right voltage and may be water damaged due to condensation. Cause: Most of the time, the water heater doesn't start because the hot water tap is not fully open, so the water flow is low. As a concerned Rheem tankless water heater user, you may want to know what causes this error code and how to fix it. See if the air inlet screen is dirty and clean as necessary. You can clean out the chamber yourself, but its best to call a professional to do it for you. Take the time to remove any obstructions from the venting as well as where the vent terminates outside. Reason: A false flame has been detected. It's best to encompass your troubleshooting to the first and second tricks, which are: Rechecking whether the exhaust venting and the air intake is working properly. Rheem tankless water heaters use a condensing technology to offer continuous hot water without the use of a large water tank. Copyright. user-manual-Tankless Hot Water Heater Rtg-74pvp-2 7.4 Gpm Manual. If your water heater is in a cold basement or garage, it may not reach this temperature unless you use a recirculating pump to bring warmer water from elsewhere in your home. Your Rheem Water Heater will trigger this error code due to a faulty remote control, a bad PCB, and a damaged wire connection between the tankless unit and the remote. This number indicates the you are dealing with. After cycling the unit if you notice any remaining flame through the view window, I bet the gas control assembly is the culprit. Now, remove the three side screws of the blower motor and take out the blower motor. local codes.The water heater requires 120 VAC/60Hz Visit Document We also broke down what you should do if the capacitor gets faulty. Check the air filter. The flow meter sensor is also referred to as a water temperature sensor. Solution: Make sure that the gas shutoff valve provides enough gas to the main gas burner, and there is no obstacle. The good news is that you can prevent most of these defects by taking good care of your water heater. In this guide, we will describe the common error codes this tankless water heater displays. Quantity Add To Cart. forms: { It will be better if you install the heat tape close to the exit to the main drain to get the best output. All LED lit (1,2,3,A,B,C) This indicates there is a problem with the internal circuit. Call the technician. When the ODS gets activated, your tankless water heater will trigger the error code 13. We recommend you read our in-depth guide on Rheem Tankless Water Heater Code 12. Technicial Manual SVC810 Second GenerationPV, X and DV, RTG2-42, RTG53, RTG66 and RTG74.pdf. There may also be blockages in the heat exchanger which should be removed. Your water heater will flash this error message on the control panel due to: Firstly, determine whether there is a problem with the remote control wiring or the remote control itself. Summary of Contents for Rheem RTGH-RH10DV. The average water heater flood claim is $4,440 1. The blower motor and flame rod FL-25 should also be checked. Check the igniter itself to ensure it is working, including how it was wired to the device. What part of Australia are you from? Learn how to inspect and replace a water heater dip tube and solve the problems related to not enough hot water or sediment buildup. Company's make changes through the years, and Rheem has been in business a long time with a wide range of tankless water heaters . Recalled Tankless Water Heaters - WebForm1 Recalled Tankless Water Heaters Paloma Rheem, Ruud, Rheem-Ruud and Richmond Brands Only the indoor power vent 199,900 BTU models are affected. Checking the main burner and cleaning it will also worth it. Our prices verses the exact same model at Homedepot.ca . The gas supply to the unit may be shut off or interrupted. 2. A tankless water heater can be a great addition to your home. IN STOCK. Unless you have an in-depth knowledge of water heaters, youre best to not risk making the situation worse. Please visit our Shutoff Troubleshooting . Ignition failure at start up. If fault re-occurs book service call. Check that the program chip is properly installed and that the control board recognizes the right type of gas, which could be propane or natural gas. Nonetheless, freezing weather can also block up the neutralizer drainage system. Reason: Insufficient Heat Exchanger Temperature. Error Code 29 indicates that the temperature is too low on the heat exchanger. If you encounter this, heres what you can do: These are the most common error codes, as well as the most common fixes for said codes. Error code 35 should require you to inspect each of the thermistor connections to the control board as they should all be securely connected. The Rheem tankless water heater code means that incomplete combustion is taking place in your heater or it may be that the water flow is too high. Use our quick reference guide to find answers to common questions or for more detailed information use the search form to search for a specific question. Please select accurately so we can provide you with the best service providers in your immediate vicinity. There are a few things that could be causing this problem. 5. When this process is completed, your water will be murky, because of the limescale that has been removed. Afterward, take out these two screws from the top of the computer board. 1. If you have a Rheem tankless water heater, you may have received a code 13 error. The vent exhaust can be a little more complicated to solve though you should start by simply checking and removing any obstructions to the exhaust vent. If nothing works for you, I suspect the PCB is the culprit. A clogged air inlet filter, dirty heat exchanger fins, and bad heat exchanger thermistor are some culprits behind this issue. emergency housing in dothan, al history of goffs manor water bird whistle history jobs at arsenal training ground hillsborough county high school athletics June 13, 2016 Read More According to Rheem, the error code 10 will pop up when the fan motor fails to create sufficient ventilation. . Troubleshooting for a switch malfunction could mean turning it off and on again by forcing a reset on the control board, all you need to do for that is press the MIN and MAX button. Every water heater venting system uses a duct or pipe. LPG users check Propane bottle level. If its too low, the unit wont work properly. On the other hand, if you can't turn on the unit, we bet the remote control gets defective. In plain words, the water heater error code 13 stands for a defective combustion system. If you get the voltage reading, take another measurement at connector B between the White#2 and White#8 wires. Remove any blockage you see. 7 Awesome Tips For Sewer And Drainage Line Cleaning, how to match wires size with circuit breaker, Hybrid Water Heaters: Everything You Need to Know. If youre getting an error code 76 on your Rheem tankless water heater, it means that the unit is not receiving enough water flow. Resetting your tankless water heater will help you clear the error code from the control panel. You may not need to contact a qualified specialist to take a look as the error codes can be troubleshot by yourself. When you have a problem . 2. } If you dont get the appropriate voltage reading (8 to 16 VDC), you should replace the water control assembly. Lastly, check the fan motor for proper operation. The most common Rheem codes are found here on Rheems official website (click on the first drop-down FAQ section). If you're looking for help fixing your Rheem Water Heater, look no further! Should the heat exchanger keep a temperature of 207 F for a period of longer than 15 seconds then error code 15 may occur. You can find a full list of error codes here. Before you make a service call, this is a good time to check the thermistor wiring for any damage or the thermistor for a limescale build-up. E5 on a Rheem Tankless Water Heater means there is a high flow rate. { Save my name, email, and website in this browser for the next time I comment. . Pipe dope may also cause a blockage inside the water flow control turbine. After that, connect the water heater directly to an electrical output source and test a hot water source like a shower. If you can solve a problem or a fault without having to make a service call then, not only will you learn more about how the water heater works, but you will likely save yourself some money. Now, remove the filter and wash it to eliminate sediment jammed in the inlet that is producing problems. Info about all performed services, including dates. Another possibility is that the water heaters thermostat is set too low and needs to be adjusted. This is another fault that you may want to check with a professional. Then, turn on the water heater again, which will reset the heater. If this drainage system gets clogged, your tankless water heater will flash the error code 29 to prevent the burner from being flooded. Again, there should be no obstructions to the airflow and the vent terminal should be clear. And thank you for mentioning your issues. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. Instead, go for non-electrolytic capacitors like ceramic or film capacitors. Connect a jumper wire to the remote terminal on the printer circuit board and try powering on the water heater using the remote control. I have installed many tank & tankless water heaters as I am a plumber. . Never had a problem or leak. Error Code 13 indicates Flame rod: poor or improper combustion. Heres what you should do: Related:Rheem Error 13 Ultimate Troubleshooting Guide. There are certain steps you can take which include checking the high and low fire manifold pressures and that the right type of gas is used. If the igniter and the fan function but the main burner doesnt, we bet one of the gas solenoid valves doesnt work properly. Locate the reset button inside the control panel. For a condensing unit, confirm that the drain line is not blocked, and the shipping cap is removed. A Rheem tankless water heater should last 15 to 20 years, and potentially longer with proper maintenance and a water supply that doesn't contain too many minerals. Contractor or business name who did the installation and service. The repair guide provides info on how to deal with the heating problems. It will likely be red and/or have a picture of a triangle with an exclamation point next to it. Remove any obstructions and try again. Check the thermostat on the remote control; it might be set too low. This particular error code could also be triggered due to the wrong altitude setting if you reside in a high-altitude environment. Check both of these things and make sure they are clear before resetting the unit again. If the gas valve was disconnected, reconnect it. Try connecting the remote control to the remote connection directly which is at the bottom of the water heater, though the cable may be the problem and could be replaced. In this guide, we will look at where you can find the most current information for your Rheem tankless water heater and look at the error codes (see also AO Smith Tankless Error Codes: Problems And Troubleshooting) in detail. In other cases, the error arises from a complex problem like a defective filter capacity. If the heater functions well, then there is an issue with the remote control. })(); Anthony Barnes is the founder of Water Heater Hub and a second-generation plumber by profession. Error code 79 should indicate that there is a problem with the current heading to the blower motor and you may want to do a service call. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Rheem offers several water heating solutions, and this article will focus on its line of tankless water heaters. For instance, the exhaust cannot be recirculated back into the units fresh air intake. . The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. Rheem Tankless Water Heater displays a lot of error codes due to specific reasons. As a basic inspection, start with verifying that there is water flow through the unit. Reason: Continuous combustion lasting an entire hour. Reason: Current fault with the Blower Motor. To resolve the issue, try the following steps: Turn off the power to the water heater for 10 seconds and then back on. Rheem ECO-180 LP by: Efren This water heater started to be a problem, 6 months after I bought it. (function() { The error code 61 popping up on the LED display represents a faulty blower motor. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Read More Propane Heater For Bed BugsContinue, Read More How Much Propane Does A Tankless Water Heater UseContinue, Read More Propane Vs Electric Water HeaterContinue, Read More Top 10 Best 80 Gallon Electric Water Heater (2022 Latest Price)Continue, Read More Top 10 Best 20 Gallon Electric Water Heater For 2022 (Buying Guide)Continue, Read More Best electric tankless water heater for rvContinue. From https://www.justanswer.com/ythiJustAnswer Customer from Chicago, Illinois: What does an error code on Rheem tankless water heater h103Pearl Wilson: Assi. No spam, we promise. Did not see that error code here. Water Heating. A flame failure is a little different from a failure to ignite and will likely require a specialist to take a look. Below, we will show you how to fix those issues to clear away the error message.